Project EnerGuard: SW/LT modules
Promoter Conception FG
Method ref. GHG quantification report, Conception FG
Tool derived from the EnerGuard GHG quantification report
How much could you save?
Adjust a few values for your vessel and instantly see the money, fuel and GHG emissions you'd save with EnerGuard.
Parameters
Adjust to match the vessel and system under study.
Fuel
Diesel/MDO or HFO: price is set below, the CO₂e factor is a constant fixed by the fuel chosen.
1.78 $/L
Default value ($1.78/L), aligned with the realistic scenario shown on the product page.
2.689 kg/L
Diesel: 2.689 kg/L. HFO: 3.176 kg/L. Fixed value, not adjustable, taken from the original technical calculator.
Pump & operation
30 kW
8760 h/an
Identical cooling pumps in service, for both reference and optimized scenarios.
60%
IMO (2020): average at-sea load is typically 40–60 % MCR.
50%
Conservative floor to keep flow realistic (default 50 %).
Thermal conditions
7 °C
Seawater temperature at the exchanger inlet.
32 °C
Limit not to exceed at the exchanger outlet.
10 °C
Rise the exchanger is designed to absorb at 100 % MCR.
25 °C
= T max outlet − T inlet. This ΔT drives the calculation below.
The max outlet temperature was automatically adjusted to stay at least 1 °C above the inlet temperature: these two values cannot contradict each other.
How these values turn into savings
Required flow ratio = %MCR × (design ΔT ÷ actual ΔT)
60 % × (10 ÷ 25) = 24 %
Pump speed retained = the greater of (minimum speed, ratio above)
max(50 %, 24 %) = 50 %
Power drawn = speed³ (centrifugal pump affinity law)
50 %³ = 12,5 % du nominal
With your current settings, it's the minimum allowed speed that caps the saving: the thermal calculation would give an even lower ratio, but the floor prevents it. Lowering the seawater temperature further would have no effect while this floor stays active; lowering the minimum speed is what would unlock more saving.
Generator set
0.276 L/kWh
225–240 g/kWh at partial load (IMO, 2020).
15%
Conservative buffer applied equally to all three scenarios alongside (pessimistic, realistic, optimistic).
Sensitivity analysis
15%
Spreads the pessimistic and optimistic scenarios around your current settings (realistic), by simultaneously varying engine load, seawater temperature, the minimum allowed speed and fuel price, proportional to this amplitude (at 15%: ±10 pts MCR, ±5 °C, ±5 pts minimum speed).
Your results
Money savings, realistic scenario
$…CAD/an
Fuel avoided, realistic scenario
…L/an
GHG reduction, realistic scenario
…t CO₂e/an
Energy savings, realistic scenario
…kWh/an
Return on investment (optional)
Financial analysisEnter the estimated implementation cost to get a payback period, under the same three scenarios. No cost is assumed.
Enter an amount to calculate the payback period.
Pessimistic… months
Realistic… months
Optimistic… months
Months to recover the investment, based on the retained savings of each scenario, before financing, incentives or maintenance.
Get a personalized follow-up
Next stepSend us the results above: a member of our team will review them and contact you.
Please fill in all four fields above (with a valid email) before sending your report.
A member of our team will contact you within 48 business hours.
Your email software has opened with the report pre-filled. Send that email to complete your request.
Prefer to reach us directly? Visit our contact page.
See the technical calculation detail
Reference vs. optimized
Reference scenarioRaw (pre-margin) annual electrical consumption
For a centrifugal pump, power varies with the cube of speed. At 50 % speed, power drops to about 12.5 % of nominal.
P/P100 = (V/V100)3
50% (speed) = 12.5% (power)
Methodology and assumptions
Quantification methodologyFlow ≈ %MCR × (design ΔT ÷ actual ΔT), capped at 100 % and floored at minimum speed.
Power ∝ speed³ (affinity law, centrifugal pump).
kWh → litres via the onboard generator; real measurements are preferable.
CO₂e includes CO₂, CH₄, N₂O (Diesel 2.689 kg/L; HFO 3.176 kg/L).
Full methodology and cited references
- The required flow ratio is approximated as %MCR × (design ΔT ÷ actual ΔT), capped at 100 % and floored at the minimum allowed speed.
- Power follows the centrifugal pump affinity law: power ∝ speed³.
- The conversion of kWh into litres of fuel depends on the auxiliary generator; onboard measurements are preferable to a generic value.
- CO₂e factors (Diesel 2.689 kg/L; HFO 3.176 kg/L) include CO₂, CH₄ and N₂O.
- The safety margin is applied uniformly to energy, fuel, GHG and dollar savings, so the figure shown is always the most conservative retained value.
Cited references
- International Maritime Organization (IMO). (2020). Fourth IMO GHG Study 2020. imo.org
- International Council on Clean Transportation (ICCT). (2024). Updating marine engine emission standards using real-world data. theicct.org
- Québec Ministry of Environment, Fight Against Climate Change, Wildlife and Parks (MELCCFP) / Transition énergétique Québec. Emission and conversion factors (diesel factor used: 2.689 kg CO₂e/L).
Illustrative estimation tool derived from Conception FG's technical calculator. To be validated by a vessel-specific engineering study before any investment decision. Does not constitute final financial or technical advice.
- Conception FG
- EnerGuard
- Calculator